19 research outputs found

    Using Global Positioning Systems (GPS) and temperature data to generate time-activity classifications for estimating personal exposure in air monitoring studies: an automated method

    Get PDF
    Background: Personal exposure studies of air pollution generally use self-reported diaries to capture individuals’ time-activity data. Enhancements in the accuracy, size, memory and battery life of personal Global Positioning Systems (GPS) units have allowed for higher resolution tracking of study participants’ locations. Improved time activity classifications combined with personal continuous air pollution sampling can improve assessments of location-related air pollution exposures for health studies. Methods: Data was collected using a GPS and personal temperature from 54 children with asthma living in Montreal, Canada, who participated in a 10-day personal air pollution exposure study. A method was developed that incorporated personal temperature data and then matched a participant’s position against available spatial data (i.e., road networks) to generate time-activity categories. The diary-based and GPS-generated time-activity categories were compared and combined with continuous personal PM2.5 data to assess the impact of exposure misclassification when using diary based methods. Results: There was good agreement between the automated method and the diary method; however, the automated method (means: outdoors = 5.1%, indoors other =9.8%) estimated less time spent in some locations compared to the diary method (outdoors = 6.7%, indoors other = 14.4%). Agreement statistics (AC1 = 0.778) suggest ‘good’ agreement between methods over all location categories. However, location categories (Outdoors and Transit) where less time is spent show greater disagreement: e.g., mean time “Indoors Other” using the time-activity diary was 14.4% compared to 9.8% using the automated method. While mean daily time “In Transit” was relatively consistent between the methods, the mean daily exposure to PM2.5 while “In Transit” was 15.9 ÎŒg/m3 using the automated method compared to 6.8 ÎŒg/m3 using the daily diary. Conclusions: Mean times spent in different locations as categorized by a GPS-based method were comparable to those from a time-activity diary, but there were differences in estimates of exposure to PM2.5 from the two methods. An automated GPS-based time-activity method will reduce participant burden, potentially providing more accurate and unbiased assessments of location. Combined with continuous air measurements, the higher resolution GPS data could present a different and more accurate picture of personal exposures to air pollution

    Household determinants of biocontaminant exposures in Canadian homes

    Get PDF
    Exposure to biocontaminants, such as dust mites, animal dander, bacteria, and mold, is associated with a range of health effects. This study identified household characteristics associated with indoor biocontaminant loadings in four Canadian cities. Floor dust was collected in 290 Canadian homes in Edmonton, Halifax, Montreal, and Windsor. The dust samples were analyzed for house dust mite allergens (Der f 1 and Der p 1), cat allergen (Fel d 1), cockroach allergen (Bla g 1), beta-(1,3)-D-glucan, and endotoxin. Household information was obtained through questionnaires and home inspections. We performed univariate and multivariate analyses to identify household determinants of biocontaminant loadings and mold odor presence. We observed large regional variations for all biocontaminants, except for cockroach allergen. The ranges of the contaminants measured in loadings and concentrations were similar to that of previous Canadian studies. Household characteristics including presence of carpeting, low floor cleaning frequency, older home age, presence of pets, and indoor relative humidity above 45% were positively associated with the presence of multiple indoor biocontaminants. High floor cleaning frequency and use of dehumidifiers were negatively associated with the presence of multiple indoor biocontaminants. Mold odor was positively associated with older home age, past water damage, and visible mold growth

    Perspectives on methyl mercury exposure locally, nationally, and globally

    Get PDF
    Methyl mercury exposure by consumption of fish and marine mammals is associated with a variety of negative health outcomes, particularly during early developmental stages. In British Columbia, there is a lack of knowledge relating to exposures in the freshwater angler population, identified elsewhere as a population at risk. Exposure assessment methods can help to characterize the risk to populations from dietary fish consumption. In Canada, the Aboriginal population is particularly vulnerable due to traditional dietary intake of fish and marine mammals; however, managing the risk from methyl mercury needs a careful approach as changing cultural practices can negatively affect social determinants of health. Globally, the use of mercury in gold mining is increasing exposure to methyl mercury among communities consuming contaminated fish. An informed understanding of patterns of exposure, health outcomes, and culture provides a basis to construct effective policies for the protection of human health

    Using Low-Cost Sensors to Assess Fine Particulate Matter Infiltration (PM2.5) during a Wildfire Smoke Episode at a Large Inpatient Healthcare Facility

    No full text
    Wildfire smoke exposure is associated with a range of acute health outcomes, which can be more severe in individuals with underlying health conditions. Currently, there is limited information on the susceptibility of healthcare facilities to smoke infiltration. As part of a larger study to address this gap, a rehabilitation facility in Vancouver, Canada was outfitted with one outdoor and seven indoor low-cost fine particulate matter (PM2.5) sensors in Air Quality Eggs (EGG) during the summer of 2020. Raw measurements were calibrated using temperature, relative humidity, and dew point derived from the EGG data. The infiltration coefficient was quantified using a distributed lag model. Indoor concentrations during the smoke episode were elevated throughout the building, though non-uniformly. After censoring indoor-only peaks, the average infiltration coefficient (range) during typical days was 0.32 (0.22–0.39), compared with 0.37 (0.31–0.47) during the smoke episode, a 19% increase on average. Indoor PM2.5 concentrations quickly reflected outdoor conditions during and after the smoke episode. It is unclear whether these results will be generalizable to other years due to COVID-related changes to building operations, but some of the safety protocols may offer valuable lessons for future wildfire seasons. For example, points of building entry and exit were reduced from eight to two during the pandemic, which likely helped to protect the building from wildfire smoke infiltration. Overall, these results demonstrate the utility of indoor low-cost sensors in understanding the impacts of extreme smoke events on facilities where highly susceptible individuals are present. Furthermore, they highlight the need to employ interventions that enhance indoor air quality in such facilities during smoke events.Applied Science, Faculty ofMedicine, Faculty ofNon UBCMechanical Engineering, Department ofMedicine, Department ofPopulation and Public Health (SPPH), School ofReviewedFacult

    Assessment of Indoor and Outdoor Air Pollution in a Residential High-Rise

    No full text
    Almost half of the world’s population resides in cities and many urban residents live in highrise apartments. It has been hypothesized that living in a highrise building might reduce exposure to ambient air pollution due to vertical gradients in outdoor air pollution and particulate removal by filtered air intake systems. However, few studies have examined air pollution levels in residential highrise buildings. Previous studies in Korea and Singapore reported significant differences in average indoor concentrations by floor (Jo and Kim, 2002; Jo et al., 2003; Jo and Lee, 2006; Kalaiarasan et al., 2009). However, extrapolation from these studies to cities in Europe and North America is difficult because of differences in construction, ventilation systems, and the components of urban pollution. This is the first study to examine the influence of vertical distribution and betweenunit infiltration on air pollutant concentrations in a Canadian residential highrise building

    Associations between personal exposure to air pollutants and lung function tests and cardiovascular indices among children with asthma living near an industrial complex and petroleum refineries

    No full text
    Objective: The acute cardiorespiratory effects of air quality among children living in areas with considerable heavy industry have not been well investigated. We conducted a panel study of children with asthma living in proximity to an industrial complex housing two refineries in Montreal, Quebec, in order to assess associations between their personal daily exposure to air pollutants and changes in pulmonary function and selected indicators of cardiovascular health. Methods: Seventy-two children with asthma age 7-12 years in 2009-2010 participated in this panel study for a period of 10 consecutive days. They carried a small backpack for personal monitoring of sulphur dioxide (SO2), benzene, fine particles (PM2.5), nitrogen dioxide (NO2) and polycyclic aromatic hydrocarbons (PAHs) and underwent daily spirometry and cardiovascular testing (blood pressure, pulse rate and oxygen saturation). To estimate these associations, we used mixed regression models, adjusting for within-subject serial correlation, and for the effects of a number of personal and environmental variables (e.g., medication use, ethnicity, temperature). Results: Children with asthma involved in the study had relatively good pulmonary function test results (mean FEV1 compared to standard values: 89.8%, mean FVC: 97.6%, mean FEF25-75: 76.3%). Median diastolic, systolic blood pressures and oxygen saturation were 60/94mmHg and 99%, respectively. Median personal concentrations of pollutants were NO2, 5.5ppb; benzene, 2.1ÎŒg/m3; PM2.5, 5.7ÎŒg/m3; and total PAH, 130ÎŒg/m3. Most personal concentrations of SO2 were below the level of detection. No consistent associations were observed between cardio-pulmonary indices and personal exposure to PM2.5, NO2 and benzene, although there was a suggestion for a small decrease in respiratory function with total concentrations of PAHs (e.g., adjusted association with FVC: -9.9ml per interquartile range 95%CI: -23.4, 3.7). Conclusions: This study suggests that at low daily average levels of exposure to industrial emissions, effects on pulmonary and cardiovascular functions in children with asthma may be difficult to detect over 10 consecutive days

    Exhaust ventilation in attached garages improves residential indoor air quality

    Get PDF
    Previous research has shown that indoor benzene levels in homes with attached garages are higher than homes without attached garages. Exhaust ventilation in attached garages is one possible intervention to reduce these concentrations. To evaluate the effectiveness of this intervention, a randomized crossover study was conducted in 33 Ottawa homes in winter 2014. VOCs including benzene, toluene, ethylbenzene, and xylenes, nitrogen dioxide, carbon monoxide, and air exchange rates were measured over four 48‐hour periods when a garage exhaust fan was turned on or off. A blower door test conducted in each garage was used to determine the required exhaust fan flow rate to provide a depressurization of 5 Pa in each garage relative to the home. When corrected for ambient concentrations, the fan decreased geometric mean indoor benzene concentrations from 1.04 to 0.40 ÎŒg/m3, or by 62% (P<.05). The garage exhaust fan also significantly reduced outdoor‐corrected geometric mean indoor concentrations of other pollutants, including toluene (53%), ethylbenzene (47%), m,p‐xylene (45%), o‐xylene (43%), and carbon monoxide (23%) (P<.05) while having no impact on the home air exchange rate. This study provides evidence that mechanical exhaust ventilation in attached garages can reduce indoor concentrations of pollutants originating from within attached garages

    diffraction structural biology 968 doi:10.1107/S0909049513021596 J. Synchrotron Rad. (2013). 20, 968–973 Journal of Synchrotron Radiation

    No full text
    The Japan Aerospace Exploration Agency (JAXA) started a high-quality protein crystal growth project, now called JAXA PCG, on the International Space Station (ISS) in 2002. Using the counter-diffusion technique, 14 sessions of experiments have been performed as of 2012 with 580 proteins crystallized in total. Over the course of these experiments, a user-friendly interface framework for high accessibility has been constructed and crystallization techniques improved; devices to maximize the use of the microgravity environment have been designed, resulting in some high-resolution crystal growth. If crystal-lization conditions were carefully fixed in ground-based experiments, high-quality protein crystals grew in microgravity in many experiments on the ISS, especially when a highly homogeneous protein sample and a viscous crystal-lization solution were employed. In this article, the current status of JAXA PCG is discussed, and a rational approach to high-quality protein crystal growth in microgravity based on numerical analyses is explained
    corecore